Session 13 Online PLUMBERS Continuing Education
State Board of Examiners of Plumbers and Gasfitters APPROVED 6 Hour Course for PLUMBERS
Message From The Director
Session 13 For Plumbers
How To Use This Course
Copyright
Learning Objectives - Section 1 Gasfitting
GAS-2A | Contact Information: Board Staff
GAS-3A | Using The NFPA-54 Handbook
GAS-4A | Using The NFPA-54 Handbook, continued
Progress Check: Using The NFPA-54 Handbook
GAS-5A | Modifications to NFPA-54: Inspection, Testing and Purging
GAS-6A | Modifications to NFPA-54, continued
GAS-7A | Testing & Inspection, continued
Progress Check: Modifications to NFPA-54
GAS-8A | Protective Coatings
Progress Check: Protective Coatings
Section 1 GAS Completed
Learning Objectives - Section 2 Gasfitting
GAS-10A | Appliances Installed in Attics
GAS-11A | Appliances Installed in Attics, continued
Progress Check: Appliances Installed in Attics
GAS-12A | Appliances Installed on Roofs
GAS-13A | Appliances Installed on Roofs, continued
Progress Check: Appliances Installed on Roofs
GAS-14A | Access to Appliances on Roofs
Progress Check: Access to Appliances on Roofs
GAS-15A | Accessibility and Clearance
GAS-16A | Accessibility and Clearance, continued
Progress Check: Accessibility and Clearance
GAS-17A | Gas Appliance Venting: Condensation
GAS-18A | Condensate: Manufacturer Instructions
Progress Check: Condensation
GAS-19A | Sidewall Venting of Gas Appliances
GAS-20A | Sidewall Venting of Gas Appliances, continued
GAS-21A | Sidewall Venting of Gas Appliances, continued
Progress Check: Sidewall Venting of Gas Appliances
GAS-22A | Guidance Summary: Gas Meter Clearances
Section 2 GAS Completed
Learning Objectives - Section 3 Gasfitting
GAS-24A | Connecting Appliances and Equipment
Progress Check: Connecting Appliances and Equipment
GAS-25A | Commercial Cooking Appliances
Progress Check: Commercial Cooking Appliances
GAS-26A | Suspended Low-Intensity Infrared Tube Heaters
Progress Check: Suspended Low-Intensity Infrared Tube Heaters
GAS-27 | Use of Nonmetallic Gas Hose Connectors
Progress Check: Use of Nonmetallic Gas Hose Connectors
GAS-28A | Connection of Portable and Mobile Industrial Appliances
Progress Check: Connection of Portable and Mobile Industrial Appliances
GAS-29A | Appliance Shutoff Valves and Connections
Progress Check: Appliance Shutoff Valves and Connections
GAS-30A | Sediment Traps
Progress Check: Sediment Traps
GAS-31A | Venting Via Damper or a Power Means of Exhaust
GAS-32A | Venting Via Damper or a Power Means of Exhaust, continued
Progress Check: Venting Via Damper or a Power Means of Exhaust
GAS-33A | Gas Valves for Fire Protection/Suppression Systems
Section 3 GAS Completed
Progress Check: Gas Valves for Fire Protection/Suppression Systems
Learning Objectives - Section 4 Gasfitting
GAS-35A | Large Gas Equipment: Definitions
Progress Check: Large Gas Equipment: Definitions
GAS-36A | Large Gas Equipment: Primary Safety Control
Progress Check: Large Gas Equipment: Primary Safety Control
GAS-37A | Large Gas Equipment: Operating Procedures
GAS-38A | Large Gas Equipment: Operating Procedures, continued
Progress Check: Large Gas Equipment: Operating Procedures
GAS-39A | Large Gas Equipment: Initial Start-Up
GAS-40A | Large Gas Equipment: Initial Startup, continued
GAS-41A | Large Gas Equipment: Initial Startup, continued
Progress Check: Large Gas Equipment: Initial Startup
GAS-42A | Fan-Assisted Gas Appliances: Basic Characteristics
GAS-43A | Fan-Assisted Gas Appliances: Sizing
GAS-44A | Fan-Assisted Gas Appliances: Sizing, continued
Progress Check: Fan Assisted Gas Appliances
GAS-45A | Fan-Assisted Gas Appliances: Connector Rise
Progress Check | Fan Assisted Gas Appliances: Sizing
GAS-46A | Fan-Assisted Gas Appliances: Vent Sizing Example
GAS-47A | Fan-Assisted Gas Appliances: Vent Sizing Example
GAS-48A | Fan-Assisted Gas Appliances: Vent Sizing Example , continued
Progress Check | Fan Assisted Gas Appliances: Sizing Examples
GAS-49A | Vent Connector Manifolds
GAS-50A | Vent Connector Manifolds, continued
GAS-51A | Vent Connector Manifolds: Sizing
Progress Check | Vent Connector Manifolds
Section 4 GAS Completed
Learning Objectives: Section 5 Gasfitting
GAS-53A | Trench Safety
GAS-54A | OSHA Fact Sheet: Trenching & Excavation Safety
GAS-56A | Trenching: Access and Egress
Progress Check: Trench Safety
GAS Section Completed!
Learning Objectives: Section 1 Plumbing
PL-2A | Hot Water
PL-3A | Hot Water, continued
PL-4A | Hot Water: Commercial Applications
PL-5A | Installation Scenario: Hot Water Temperatures
PL-6A | Installation Scenario: Hot Water Temperatures
Progress Check: Hot Water: Commercial Applications
PL-7A | Disinfection of Potable Water Systems
PL-8A | Disinfection of Potable Water Systems, MA DEP
PL-9A | Disinfection of Potable Water Systems, EPA
Progress Check: Disinfection of Potable Water Systems
PL-11A | Prohibited Venting: Combination Waste & Vent System
Progress Check: Prohibited Venting: Combination Waste & Vent System
PL-12A | Prohibited Venting: Crown Venting Limitation
Progress Check: Prohibited Venting: Crown Venting Limitation
PL-13A | Prohibited Venting: Extension of Horizontal Drain
PL-14A | Prohibited Venting: Below Trap Weir
PL-15A | Vent Terminals
PL-16A | Vent Terminals, continued
Progress Check: Prohibited Venting
Section 1 PLUMBING Completed!
Learning Objectives: Section 2 Plumbing
PL-11A | Prohibited Venting: Combination Waste & Vent System
Progress Check: Prohibited Venting: Combination Waste & Vent System
PL-12A | Prohibited Venting: Crown Venting Limitation
Progress Check: Prohibited Venting: Crown Venting Limitation
PL-13A | Prohibited Venting: Extension of Horizontal Drain
PL-14A | Prohibited Venting: Below Trap Weir
PL-15A | Vent Terminals: Location
PL-16A | Vent Terminals, continued
Progress Check: Prohibited Venting & Vent Terminals
PL-17A | Vent Terminals: Location
PL-18A | Vent Extensions Outside of Buildings
PL-19A | Wet Venting
Progress Check: Vent Terminals & Vent Extensions
PL-20A | Wet Venting, continued
Progress Check: Wet Venting
PL-21A | Common Vents
PL-22A | Common Vents
PL-23A | Common Vents, continued
PL-24A | Common Vents, continued
Progress Check: Common Venting
Section 2 PLUMBING Completed!
Learning Objectives: Section 3 Plumbing
PL-26A | Trap Primers
Progress Check | Trap Primers
PL-27A | Service Sinks
PL-28A | Service Sinks, continued
Progress Check | Service Sinks
PL-29A | Drinking Water Stations
PL-30A | Drinking Water Stations: 248 CMR 10.10(18) Table 1, Excerpts
Progress Check | Drinking Water Stations
PL-31A | Board Advisory: Elevator Sumps
Progress Check | Board Advisory: Elevator Sumps
PL-32A | Building Height Determination
Progress Check | Building Height Determination
Progress Check | Sanitary Drainage System: Fixture Units
PL-33A | Suds Relief Vents
PL-34A | Suds Relief Vents, continued
Progress Check | Suds Relief Vents
PL-35A | So-Vent Plumbing Systems
PL-36A | So-Vent Plumbing Systems, continued
Progress Check | So-Vent Plumbing Systems
PL-37A | Outdoor Kitchens
Section 3 PLUMBING Completed!
Learning Objectives: Section 4 Plumbing
PL-39A | Demolition and Removal
Progress Check | Demolition and Removal
PL-40A | Changes in Direction of Drainage Piping
Progress Check | Changes in Direction of Drainage Piping
PL-41A | Fittings and Connections Prohibited
PL-42A | Fittings and Connections Prohibited, continued
Progress Check | Fittings and Connections Prohibited
PL-43A | Indirect Waste Piping: Swimming Pools
Progress Check | Indirect Waste Piping: Swimming Pools
PL-44A | Storm Drains
PL-45A | Storm Drains, continued
Progress Check | Storm Drains
PL-46A Board Policy: Secondary Roof Drains
PL-47A | Board Policy: Secondary Roof Drains, continued
PL-48A | Board Policy: Secondary Roof Drains, continued
Progress Check | Secondary Roof Drains
Section 4 PLUMBING Completed!
Learning Objectives: Section 5 Plumbing
PL-50A | Infection Control & Worker Safety: Introduction
PL-51A | Micro-organisms
Progress Check | Micro-organisms
PL-52A | Pathogens
PL-53A | Pathogens: Mode of Transmission
PL-54A | Pathogens: Mode of Transmission, continued
Progress Check | Pathogens
PL-55A | Worker Safety: OSHA Training
PL-56A | Legionella & Water Temperature
PL-57A | Legionella & Water Temperature, continued
Progress Check | Legionella
PL-58A | Worker Protection: Water Supply
PL-59A | Worker Protection: DWV System
PL-60A | Worker Protection: DWV System, continued
PL-61A | Worker Protection: COVID-19
PL-62A | Worker Protection: COVID-19 Transmission
PL-63A | Worker Protection: COVID-19 Transmission, continued
Progress Check: Worker Protection: DWV System, continued
Session 13 Completed!